GEORGIA
GEORGIA
+995 511 560 055 Mon - Fri 09:00 - 18:00 22 Bakhtrioni street, apartment 75. Tbilisi
Energy Distribution
0.4-10kV Switchgears
Electic Drive
Motors & Drives
Transformers
Dry & Oil immersed
Get A Quote

Low voltage equipment

Caption aligned here
UNIGRON > Our Solutions > Low voltage equipment

LV Components

0,4kV

Main Switchboards (MDB / MSB)

Power intake and primary distribution

Rated current: up to 6300A
Thermal withstand current (1 sec): up to 100kA
Electrodynamic withstand current: up to 220kA
Climatic versions: UHL3, UHL3.1, T3, OM4, UHL4, UHL4.2
Ambient temperature range: -25°C to +50°C
Installation altitude above sea level: up to 1000m*
Seismic resistance: up to 9 points on the MSK-64 scale
Protection degree: IP31, IP41, IP54, IP55

With fixed modules and plug-in or withdrawable switching devices
With withdrawable modules
Available in both front and rear access configurations
Internal separation (segmentation) up to 4B
Equipped with an electromechanical interlocking system
Supports cable and busbar connections
Fitted with protective screens against accidental contact

Motor Control Centers (MCC)

Control and protection of motor-driven systems

Rated current: up to 6300A
Thermal withstand current (1 sec): up to 100kA
Electrodynamic withstand current: up to 220kA
Climatic versions: UHL3, UHL3.1, T3, OM4, UHL4, UHL4.2
Ambient temperature range: -25°C to +50°C
Installation altitude above sea level: up to 1000m*
Seismic resistance: up to 9 points on the MSK-64 scale
Protection degree: IP31, IP41, IP54, IP55

With fixed modules and plug-in or withdrawable switching devices
With withdrawable modules
Available in both front and rear access configurations
Internal separation (segmentation) up to 4B
Equipped with an electromechanical interlocking system
Supports cable and busbar connections
Fitted with protective screens against accidental contact

Distribution Boards (DB / SDB)

Secondary and local power distribution

Rated current: up to 6300A
Thermal withstand current (1 sec): up to 100kA
Electrodynamic withstand current: up to 220kA
Climatic versions: UHL3, UHL3.1, T3, OM4, UHL4, UHL4.2
Ambient temperature range: -25°C to +50°C
Installation altitude above sea level: up to 1000m*
Seismic resistance: up to 9 points on the MSK-64 scale
Protection degree: IP31, IP41, IP54, IP55

With fixed modules and plug-in or withdrawable switching devices
With withdrawable modules
Available in both front and rear access configurations
Internal separation (segmentation) up to 4B
Equipped with an electromechanical interlocking system
Supports cable and busbar connections
Fitted with protective screens against accidental contact